IMPORTANT NOTE: Ensure any rebate strips or door stops are fi tted before proceeding.
For double-leaf doors, the inactive leaf must be securely fi xed in the closed position and a rebate strip fi tted to prevent
door over-travel.
Strike is suitable for 15mm latches, based on a 3mm door gap.
INSTALLATION INSTRUCTIONS
200/2000 SERIES ELECTRIC STRIKE
Mark positions X and Y of door latchbolt on door jamb (see Fig. 1).
Remove the backing of supplied stick-on template, and apply to door jamb. Ensure the lines “Front face of Lock Latch” on both template
and door jamb are aligned (see Note 1).
Scribe the door jamb according to template outline (see Fig. 2).
Prepare door jamb as per appropriate installation type; for Metal Jamb refer to Fig. 3, for Wood Jamb refer to Fig. 4. Install mounting tabs
where applicable. (see Note 2).
Ensure all wiring is correctly connected and not rubbing on sharp edges or interfering with any strike mechanism.
Install the strike temporarily in position and check there is no interference between the door, strike and lock face plates, and the extension
lip of strike during door closing. Ensure the deadlatching auxiliary bolt does not enter the strike keeper area when door is closed.
Check there is no pressure on the strike keeper when door is closed.
When all above checks are complete, secure strike with appropriate screws and re-check operation.
NOTE 1 : A 1mm clearance has been designed into the template to prevent the door exerting pressure on the strike when closed.
NOTE 2 : Allow suffi cient space between the electric strike unit and jamb cut-out for the wires. Bunching of wires may cause the unit
to malfunction.
1.
2.
3.
4.
5.
6.
7.
8.
Fig. 2 - 200/2000 Series Electric Strike Template Outline
Fig. 1 - Door Frame Preparation
Align with
“Front Face
of Lock
Latch” line
on Template
y
x
y
X
X
y
or
Bevelled Face
*These dimensions have a tolerance of +0.8mm/-0
161mm
Keeper Width
38mm
Limits of Extension Lip
100mm
*123mm
*176.21mm
*29mm
*44.5mm
Front Face of Lock Latch
NOT TO SCALE
P
age
1
DRAWINGS NOT TO SCALE. INFORMATION IN THIS DATASHEET MAY BE CHANGED WITHOUT NOTICE.
P
age
4
200/2000 SERIES SPARE PARTS & ACCESSORIES
The following are available as optional extras:
SPARE PARTS
* When the use of extension lips is required, the standard model numbers of electric strikes must be suffi xed with “X” to denote
pre-drilled extension holes (e.g. 2000X).
25mm extension lip (A),
50mm extension lip (B)
75mm extension lip (C)
available as optional extras.
B
50mm
A
25mm
75mm
C
xx
y
y
Door Edge
or
Mortice Lock
Tubular/Cylindrical
Latch
Part Number Qty Per Pack Description
220200-501 1 Solenoid Status Microswitch Assembly
220200-502 1 Door Latch Microswitch Assembly
220200-504 1 set Screw Kit - Installation
220200-508 5 x (2 short, 1 long) Locking Pins
220200-511 5 200 Series Locking Pin Return Spring
220200-520 5 Spring - Microswitch Retainer
220200-513 1 12 V Solenoid Coil
220200-514 1 24 V Solenoid Coil
220200-515 1 48 V Solenoid Coil
ACCESSORIES
Part Number Qty Per Pack Description
220200-519 1 Mounting Kit
220200-505 1 25mm Extension Lip *
220200-506 1 50mm Extension Lip *
220200-507 1 75mm Extension Lip *
5 Year Limited Warranty
ASSA ABLOY Australia guarantees for a period of 5 years in accordance with Trimec’s Standard Warranty Conditions, against defects in
manufacture, workmanship or materials, provided that all electrical and mechanical installation requirements are adhered to as per this
datasheet. All third party and consequential claims are expressly excluded from this warranty.
warranty
An ASSA ABLOY Group brand
DA0002, Issue 10: 25th July 2007
ASSA ABLOY Australia
2/16 Atkinson Road
Taren Point 2229
NSW, Australia
www.assaabloyasiapacifi c.com
Page view 0
1 2

Summary of Contents

Page 1 - SPARE PARTS & ACCESSORIES

IMPORTANT NOTE: Ensure any rebate strips or door stops are fi tted before proceeding. For double-leaf doors, the inactive leaf must be securely fi xed i

Page 2 - ELECTRICAL SPECIFICATIONS

To change the electric strike’s mode of lock operation, remove the back cover and the 2 screws securing the solenoid. Remove solenoid from strike hous

Comments to this Manuals

No comments

Timex 622 095000 NA podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Krokomierze Timex 622 095000 NA.
Dostarczamy 1 pdf podręczników Timex 622 095000 NA do pobrania za darmo według typów dokumentów: Instrukcja Użytkownika


Timex 622 095000 NA Instrukcja Użytkownika (2 strony)


Marka: Timex | Kategoria: Pedometers | Rozmiar: 0.16 MB |

    

Spis treści





Więcej produktów i instrukcji dla Krokomierze Timex

Modele Rodzaj dokumentu
620 095000 Instrukcja Użytkownika      Timex 620 095000 User's Manual, 2 strony